TABLE 2. TROUBLESHOOTING GUIDE
DEFECT
POSSIBLE CAUSE
P A Idling Current
Unstable
1. Defective Power Amplifier Tube (V4).
2. Defective BIAS control and/or associated components.
3. Defective bias power supply.
Inability to Load per
Operation Instructions
1. Antenna not resonant at operating frequency.
2 Defective transmission line.
3. Defective antenna loading coi1(s).
4. Tubes VI through V4 defective.
Insufficient Sideband
Suppression
1. Carrier Oscillator (Q3) operating on incorrect frequency.
2. Crystal fllter defective or mistuned.
Insufficient Carrier
Suppression
1. Tube V13 defective.
2. Transformer T1301 defective or mistuned.
3. Oirrier O~i11ator (Q3) operating on incorrect frequency.
Microphonics in Transmitter
r:'I'iibes V13 and/or V14 defective.
2. IF coil 1701 Defective or incorrectly adjusted.
3. Microphone defective.
Low Receiver Sensitivity
1. Tubes VS through VIO defective.
2. mcorrect adjustment of the transmitter Pi-Network.
3. IF coil L80I incorrectly adjusted or defective.
4. Kl relay contacts defective.
TABLE 3. VFO AND CARRIER OSCILLATOR FREQUENCIES